Difference between revisions of "User:Jhurley/sandbox"
(→HPLC-UV and MS Methods) |
(→Low Concentration Waters (< 1 ppm)) |
||
Line 104: | Line 104: | ||
|+Table 2. Primary HPLC-UV mobile phase gradient method concentrations | |+Table 2. Primary HPLC-UV mobile phase gradient method concentrations | ||
|- | |- | ||
− | | colspan="5" style="background-color:white;"| Method run time = 48 minutes; Column temperature = 25°C | + | | colspan="5" style="background-color:white;"| Method run time = 48 minutes; Column temperature = 25°C<br>Injection volume = 50 μL; Flow rate = 1.0 mL/min<br>Detector wavelengths = 210, 254, and 310 nm |
|- | |- | ||
! Time<br>(min) | ! Time<br>(min) |
Revision as of 13:20, 25 July 2024
Munitions Constituents – Sample Extraction and Analytical Techniques
Munitions Constituents, including insensitive munitions IM), are a broad category of compounds and, in areas where manufactured or used, can be found in a variety of environmental matrices (waters, soil, and tissues). This presents an analytical challenge when a variety of these munitions are to be quantified. This article discusses sample extraction methods for each typical sample matrix (high level water, low level water, soil and tissue) as well as the accompanying HPLC-UV analytical method for 27 compounds of interest (legacy munitions, insensitive munitions, and surrogates).
Related Article(s):
Contributor(s):
- Dr. Austin Scircle
Key Resource(s):
- Methods for simultaneous quantification of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices[2]
Introduction
Compound | Acronym | CAS Number |
---|---|---|
1,2-Dinitrobenzene (surrogate) | 1,2-DNB (surr.) | 528-29-0 |
1,3-Dinitrobenzene | 1,3-DNB | 99-65-0 |
1,3,5-Trinitrobenzene | 1,3,5-TNB | 99-35-4 |
1,4-Dinitrobenzene | 1,4-DNB (surr.) | 100-25-4 |
2-Amino-4,6-dinitrotoluene | 2-Am-4,6-DNT | 35572-78-2 |
2-Nitrophenol | 2-NP | 88-75-5 |
2-Nitrotoluene | 2-NT | 88-72-2 |
2,4-Dinitrophenol | 2,4-DNP | 51-28-5 |
2,4-Dinitrotoluene | 2,4-DNT | 121-14-2 |
2,4,6-Trinitrophenol | Picric Acid (PA) | 88-89-1 |
2,4,6-Trinitrotoluene | 2,4,6-TNT | 118-96-7 |
2,6-Dinitrotoluene | 2,6-DNT | 606-20-2 |
3-Nitrotoluene | 3-NT | 99-08-1 |
3,5-Dinitroaniline | 3,5-DNA | 618-87-1 |
4-Amino-2,6-dinitrotoluene | 4-Am-2,6-DNT | 19406-51-0 |
4-Nitrophenol | 4-NP | 100-02-7 |
4-Nitrotoluene | 4-NT | 99-99-0 |
2,4-Dinitroanisole | DNAN | 119-27-7 |
Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine | HMX | 2691-41-0 |
Nitrobenzene | NB | 98-95-3 |
Nitroglycerine | NG | 55-63-0 |
Nitroguanidine | NQ | 556-88-7 |
3-Nitro-1,2,4-triazol-5-one | NTO | 932-64-9 |
ortho-Nitrobenzoic acid | o-NBA (surr.) | 552-16-9 |
Pentaerythritol tetranitrate | PETN | 78-11-5 |
Hexahydro-1,3,5-trinitro-1,3,5-triazine | RDX | 121-82-4 |
N-Methyl-N-(2,4,6-trinitrophenyl)nitramide | Tetryl | 479-45-8 |
Note: Analytes in bold are not identified by EPA Method 8330B. |
The primary intention ;of the analytical methods presented here is to support the monitoring of legacy and insensitive munitions contamination on test and training ranges, however legacy and insensitive munitions often accompany each other at demilitarization facilities, manufacturing facilities, and other environmental sites. Energetic materials typically appear on ranges as small, solid particulates and due to their varying functional groups and polarities, can partition in various environmental compartments[3]. To ensure that contaminants are monitored and controlled at these sites and to sustainably manage them a variety of sample matrices (surface or groundwater, process waters, soil, and tissues) must be considered. (Process water refers to water used during industrial manufacturing or processing of legacy and insensitive munitions.) Furthermore, additional analytes must be added to existing methodologies as the usage of IM compounds changes and as new degradation compounds are identified. Of note, relatively new IM formulations containing NTO, DNAN, and NQ are seeing use in IMX-101, IMX-104, Pax-21 and Pax-41 (Table 1)[4][5].
Sampling procedures for legacy and insensitive munitions are identical and utilize multi-increment sampling procedures found in USEPA Method 8330B Appendix A[1]. Sample hold times, subsampling and quality control requirements are also unchanged. The key differences lie in the extraction methods and instrumental methods. Briefly, legacy munitions analysis of low concentration waters uses a single cartridge reverse phase SPE procedure, and acetonitrile (ACN) is used for both extraction and elution for aqueous and solid samples[1][6]. An isocratic separation via reversed-phase C-18 column with 50:50 methanol:water mobile phase or a C-8 column with 15:85 isopropanol:water mobile phase is used to separate legacy munitions[1]. While these procedures are sufficient for analysis of legacy munitions, alternative solvents, additional SPE cartridges, and a gradient elution are all required for the combined analysis of legacy and insensitive munitions.
Previously, analysis of legacy and insensitive munitions required multiple analytical techniques, however the methods presented here combine the two munitions categories resulting in an HPLC-UV method and accompanying extraction methods for a variety of common sample matrices. A secondary HPLC-UV method and a HPLC-MS method were also developed as confirmatory methods. The methods discussed in this article were validated extensively by single-blind round robin testing and subsequent statistical treatment as part of ESTCP ER19-5078. Wherever possible, the quality control criteria in the Department of Defense Quality Systems Manual for Environmental Laboratories were adhered to[7]. Analytes included in these methods are found in Table 1.
The chromatograms produced by the primary and secondary HPLC-UV methods are shown in Figure 1 and Figure 2, respectively. Chromatograms for each detector wavelength used are shown (315, 254, and 210 nm).
Extraction Methods
High Concentration Waters (> 1 ppm)
Aqueous samples suspected to contain the compounds of interest at concentrations detectable without any extraction or pre-concentration are suitable for analysis by direct injection. The method deviates from USEPA Method 8330B by adding a pH adjustment and use of MeOH rather than ACN for dilution[1]. The pH adjustment is needed to ensure method accuracy for ionic compounds (like NTO or PA) in basic samples. A solution of 1% HCl/MeOH is added to both acidify and dilute the samples to a final acid concentration of 0.5% (vol/vol) and a final solvent ratio of 1:1 MeOH/H2O. The direct injection samples are then ready for analysis.
Low Concentration Waters (< 1 ppm)
Aqueous samples suspected to contain the compounds of interest at low concentrations require extraction and pre-concentration using solid phase extraction (SPE). The SPE setup described here uses a triple cartridge setup shown in Figure 3. Briefly, the extraction procedure loads analytes of interest onto the cartridges in this order: StrataTM X, StrataTM X-A, and Envi-CarbTM. Then the cartridge order is reversed, and analytes are eluted via a two-step elution, resulting in 2 extracts (which are combined prior to analysis). Five milliliters of MeOH is used for the first elution, while 5 mL of acidified MeOH (2% HCl) is used for the second elution. The particular SPE cartridges used are noncritical so long as cartridge chemistries are comparable to those above.
Method run time = 48 minutes; Column temperature = 25°C Injection volume = 50 μL; Flow rate = 1.0 mL/min Detector wavelengths = 210, 254, and 310 nm | ||||
Time (min) |
Reagent Water (%) |
MeOH (%) |
0.1% TFA/Water (%) |
ACN (%) |
---|---|---|---|---|
0.00 | 89 | 3 | 3 | 5 |
2.00 | 89 | 3 | 3 | 5 |
2.20 | 52 | 40 | 3 | 5 |
12.5 | 52 | 40 | 3 | 5 |
19.0 | 57 | 35 | 3 | 5 |
28.0 | 48 | 44 | 3 | 5 |
32.0 | 48 | 44 | 3 | 5 |
44.0 | 32 | 60 | 3 | 5 |
44.1 | 89 | 3 | 3 | 5 |
48.0 | 89 | 3 | 3 | 5 |
Soils
Soil collection, storage, drying and grinding procedures are identical to the USEPA Method 8330B procedures[1]; however, the solvent extraction procedure differs in the number of sonication steps, sample mass and solvent used. A flow chart of the soil extraction procedure is shown in Figure 4. Soil masses of approximately 2 g and a sample to solvent ratio of 1:5 (g/mL) are used for soil extraction. The extraction is carried out in a sonication bath chilled below 20 ⁰C and is a two-part extraction, first extracting in MeOH (6 hours) followed by a second sonication in 1:1 MeOH:H2O solution (14 hours). The extracts are centrifuged, and the supernatant is filtered through a 0.45 μm PTFE disk filter.
The solvent volume should generally be 10 mL but if different soil masses are required, solvent volume should be 5 mL/g. The extraction results in 2 separate extracts (MeOH and MeOH:H2O) that are combined prior to analysis.
Tissues
Tissue matrices are extracted by 18-hour sonication using a ratio of 1 gram of wet tissue per 5 mL of MeOH. This extraction is performed in a sonication bath chilled below 20 ⁰C and the supernatant (MeOH) is filtered through a 0.45 μm PTFE disk filter.
Due to the complexity of tissue matrices, an additional tissue cleanup step, adapted from prior research, can be used to reduce interferences[8][2]. The cleanup procedure uses small scale chromatography columns prepared by loading 5 ¾” borosilicate pipettes with 0.2 g activated silica gel (100–200 mesh). The columns are wetted with 1 mL MeOH, which is allowed to fully elute and then discarded prior to loading with 1 mL of extract and collecting in a new amber vial. After the extract is loaded, a 1 mL aliquot of MeOH followed by a 1 mL aliquot of 2% HCL/MeOH is added. This results in a 3 mL silica treated tissue extract. This extract is vortexed and diluted to a final solvent ratio of 1:1 MeOH/H2O before analysis.
HPLC-UV and MS Methods
Method run time = 43 minutes; Column temperature = 25°C; Injection volume = 50 μL Flow rate = 0.8 mL/min; Detector wavelengths = 210, 254, and 310 nm | ||||
Time (min) |
Reagent Water (%) |
MeOH (%) |
0.1% TFA/Water (%) |
ACN (%) |
---|---|---|---|---|
0.00 | 75 | 10 | 10 | 5 |
2.50 | 75 | 10 | 10 | 5 |
2.60 | 39 | 46 | 10 | 5 |
9.00 | 39 | 46 | 10 | 5 |
9.10 | 33.5 | 51.5 | 10 | 5 |
15.00 | 35 | 50 | 10 | 5 |
15.10 | 43 | 42 | 10 | 5 |
33.00 | 30 | 55 | 10 | 5 |
33.10 | 75 | 10 | 10 | 5 |
43.00 | 75 | 10 | 10 | 5 |
Parameter | Value |
---|---|
Ionization Source | APCI |
Ionization Mode | Negative |
Drying Gas Temperature (°C) | 350 |
Vaporizer Temperature (°C) | 325 |
Drying Gas Flow (L/min) | 4.0 |
Nebulizer Pressure (psig) | 40 |
Corona Current (μA) | 10 |
Capillary Potential (V) | 1500 |
Mass Range | 40 – 400 |
Fragmentor | 100 |
Gain | 1 |
Threshold | 0 |
Step Size | 0.20 |
Speed (μ/sec) | 743 |
Peak Width (min) | 0.06 |
Cycle Time (sec/cycle) | 0.57 |
The Primary HPLC method uses a Phenomenex Synergi 4 µm Hydro-RP column (80Å, 250 x 4.6 mm), or comparable, and is based on both the HPLC method found in USEPA 8330B and previous work[1][8][2]. This separation relies on a reverse phase column and uses a gradient elution, shown in Table 2. Depending on the analyst’s needs and equipment availability, the method has been proven to work with either 0.1% TFA or 0.25% FA (vol/vol) mobile phase. Addition of a guard column like a Phenomenex SecurityGuard AQ C18 pre-column guard cartridge can be optionally used. These optional changes to the method have no impact on the method’s performance. The Secondary HPLC method uses a Restek Pinnacle II Biphenyl 5 µm (150 x 4.6 mm) or comparable column and is intended as a confirmatory method. Like the Primary method, this method can use an optional guard column and utilizes a gradient elution, shown in Table 3.
For instruments equipped with a mass spectrometer (MS), a secondary MS method is available and was developed alongside the Primary UV method. The method was designed for use with a single quadrupole MS equipped with an atmospheric pressure chemical ionization (APCI) source, such as an Agilent 6120B. A majority of the analytes shown in Table 1 are amenable to this MS method, however nitroglycerine (which is covered extensively in USEPA method 8332) and 2-,3-, and 4-nitrotoluene compounds aren’t compatible with the MS method. MS method parameters are shown in Table 4.
Summary
The extraction methods and instrumental methods in this article build upon prior munitions analytical methods by adding new compounds, combining legacy and insensitive munitions analysis, and expanding usable sample matrices. These methods have been verified through extensive round robin testing and validation, and while the methods are somewhat challenging, they are crucial when simultaneous analysis of both insensitive and legacy munitions is needed.
References
- ^ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 United States Environmental Protection Agency (USEPA), 2006. EPA Method 8330B (SW-846) Nitroaromatics, Nitramines, and Nitrate Esters by High Performance Liquid Chromatography (HPLC), Revision 2. USEPA Website EPA Method 8330b
- ^ 2.0 2.1 2.2 Crouch, R.A., Smith, J.C., Stromer, B.S., Hubley, C.T., Beal, S., Lotufo, G.R., Butler, A.D., Wynter, M.T., Russell, A.L., Coleman, J.G., Wayne, K.M., Clausen, J.L., Bednar, A.J., 2020. Methods for simultaneous determination of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices. Talanta, 217, Article 121008. doi: 10.1016/j.talanta.2020.121008 Open Access Manuscript.pdf
- ^ Walsh, M.R., Temple, T., Bigl, M.F., Tshabalala, S.F., Mai, N. and Ladyman, M., 2017. Investigation of Energetic Particle Distribution from High‐Order Detonations of Munitions. Propellants, Explosives, Pyrotechnics, 42(8), pp. 932-941. doi: 10.1002/prep.201700089
- ^ Mainiero, C. 2015. Picatinny Employees Recognized for Insensitive Munitions. U.S. Army, Picatinny Arsenal Public Affairs. Open Access Press Release
- ^ Frem, D., 2022. A Review on IMX-101 and IMX-104 Melt-Cast Explosives: Insensitive Formulations for the Next-Generation Munition Systems. Propellants, Explosives, Pyrotechnics, 48(1), e202100312. doi: 10.1002/prep.202100312
- ^ United States Environmental Protection Agency (USEPA), 2007. EPA Method 3535A (SW-846) Solid-Phase Extraction (SPE), Revision 1. USEPA Website Method 3535A.pdf
- ^ US Department of Defense and US Department of Energy, 2021. Consolidated Quality Systems Manual (QSM) for Environmental Laboratories, Version 5.4. 387 pages. Free Download QSM Version 5.4.pdf
- ^ 8.0 8.1 Russell, A.L., Seiter, J.M., Coleman, J.G., Winstead, B., Bednar, A.J., 2014. Analysis of munitions constituents in IMX formulations by HPLC and HPLC-MS. Talanta, 128, pp. 524–530. doi: 10.1016/j.talanta.2014.02.013